WE SAFE YOUR LIFE

  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
فاير اند | Fire end فاير اند | Fire end
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
Search
Menu
Home TELETEK Modules SensoIRIS MiniOut
SF50
Back to products
SensoIRIS MIMIC

SensoIRIS MiniOut

Relay switching power 60W, 62.5VA
Relative humidity resistance (93±3)%@+40°C
Operating voltage 15 ÷ 32V DC
Max. current consumption 0.1mA
Relay ratings 0.25A/24V AC; 2A/30V DC
Relay rated current 2A
Relay max. switching current 5A
Protection (with enclosure box) IP30
Relative humidity resistance (93±3)%@+40°C
Max. cross section of the cables 2.5mm2
Dimensions (PCB) 43x25mm
Mounting Indoor use

 

Add to wishlist
Categories: Addressables, Modules
Share:
  • Description
  • Attachment
Description

Description

SensoIRIS MiniOUT is a compact addressable module with single non-monitored output. The module is designed for built-in installation in the external devices or directly for wall mounting. SensoIRIS MiniOUT is powered bythe fire panel . The non-monitored relay output is suitable to switch of 24V AC voltage circuits. The output terminals are wired with color cables for easy recognition during the module’s installation. SensoIRIS MiniOUT complies with the requirements of EN54-18.

  • Compact size
  • One non-monitored output
  • Powered from the fire panel
  • Color cables for easy recognition
  • Complies with the requirements of EN54-18
  • Compatible with Teletek Addressable control panels iRIS 4 / 8 and Simpo
Attachment

Datasheet

Download

Related products

Compare

Manual Call Point

alarms, Addressables, LIFECO, Fire Alarm & Low Current System
Operating voltage 9 ÷ 30 VDC Nominal operating voltage 24 VDC Current consumption in alarm state 23mA/15V; 38mA/24V; 48mA/30V Installation wires 0,4mm2 ÷ 2.0mm2 Operation temperature -10°C ÷ +60°C Relative humidity ≤93% @ +40°C Type of the frangible element A Material (plastic), Color ABS, red Degree of protection IP40 Dimensions (incl. base) 90x57x90mm
Add to wishlist
Quick view
Compare

Robin fire alarm addressable control panel

alarms, Addressables, LIFECO, Fire Alarm & Low Current System
Model Number: LF-6100A/1, LF-6100A/2 & LF-6100A/4 Attributes Available in 1, 2 and 4 Smart Detection Circuits 5" LCD Display - 320 x 240 dpi Resolution Up to 127 devices each episode. Logic-controlled output functions 15 LED status indicators 21 user-friendly control keys Laptop programming Full field programming
Add to wishlist
Quick view
Compare

Signal Input Module

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Features

  • Low Profile Design
  • Built-in CPU
  • Interfaces Normally Open Dry Contacts
  • ALARM FIRST! – Less than 1 second
  • Data Transfer Speed and Reliability
  • Polarized Wiring
  • LED Status Indicators
  • High Performance at Low Cost
  • Two Wire System
  • Use LF-DP-6190 for device addressing
Add to wishlist
Quick view
Compare

Optical – Smoke Fire Alarm Detector

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Application

The S30 is a high sensitive optical smoke detector. It is suitable for applications where early detection of smoke or fire is with great importance, for example office buildings, supermarkets, schools, etc.
Add to wishlist
Quick view
Compare

SensoIRIS T110

alarms, Addressables, TELETEK
Operating Voltage Range 15-32VDC (Nom. 27VDC)
Consumption in quiescent state, no communication < 130μA@27VDC
Consumption in quiescent state, with communication < 180μA@27VDC
Consumption in alarm state, with communication 6.5mA
Output in alarm state at terminal RI (terminals 4/ 1) 7.5 mA (max)/ 7.5V
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +65°C
Protection IP30
Weight (including base) ~110g
Dimensions (including base) 103x42mm
Add to wishlist
Quick view
Hot
Compare

MCP Cover Set

alarms, Addressables, Conventional, TELETEK
Compatible with SensoMAG MCP50 and SensoIRIS MCP150
Add to wishlist
Quick view
Compare

iRIS8 B

Addressables, Control panel
Main Power Supply  110÷230VAC,50÷60 Hz, 2x200W
 Back-up Power Supply- lead batteries one in the main block + one in the Block expander 12V/ 18Ah
Nominally internal battery resistance  <0,3Ohm
Storage Temperature -10˚C to +60˚C
Operating temperature -5°C to +40°C
Dust and moisture protection IP30
Relative Humidity (without condense) up to 95%
Dimensions 660/430/120mm
 Weight 15kg (without battery)
Add to wishlist
Quick view
Compare

SensoIRIS MCP150

alarms, Addressables, TELETEK, Sirens
Operating Voltage Range 15 – 32VDC
Consumption without communication (max) 125μA@27VDC
Consumption in Fire mode 3mA
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP40
Weight ~175g
Dimensions 90x90x57mm
Add to wishlist
Quick view
  • Riyadh, Malaz, At the intersection of Salah al-Din and Al - Sahrawi St. ​
  • Phone: (+966) 580709087
  • Phone: (+966) 593847589
  • Admin@fireendtrading.com
  • USEFUL Pages
    • About Us
    • Products
    • Our Projects
    • Certificates
    • Contact Us
  • Categories
    • Alarms
    • Boxes
    • Extinguishers
    • PUMPS
    • Sprinkler
    • Fire Hydrants
    • Valves
    • Pressure Tanks
  • Addressable analog control panel
  • 2 zone fire alarm control panel
  • Mobile CO2 Fire Extinguishers
  • Standard Fire Pumps Systems
  • SF 200
Based on Fire End Trading theme 2023 GK.
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
Start typing to see products you are looking for.
Wishlist
Compare
Shop