WE SAFE YOUR LIFE

  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
فاير اند | Fire end فاير اند | Fire end
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
Search
Menu
Home TELETEK Control panel iRIS8 B
Fire Extinguisher Cabinets
Back to products
SensoIRIS S130

iRIS8 B

Main Power Supply  110÷230VAC,50÷60 Hz, 2x200W
 Back-up Power Supply- lead batteries

one in the main block + one in the Block expander

12V/ 18Ah
Nominally internal battery resistance  <0,3Ohm
Storage Temperature -10˚C to +60˚C
Operating temperature -5°C to +40°C
Dust and moisture protection IP30
Relative Humidity

(without condense)

up to 95%
Dimensions 660/430/120mm
 Weight 15kg (without battery)
Add to wishlist
Categories: Addressables, Control panel
Share:
  • Description
  • Attachment
Description

Description

  • Expandable from 1 to 8 loop controllers
  • 2000 devices per system
  • 10 000 events log
  • 7” TFT Touch Screen
  •  Multilanguage menu
  • 200 Zone LED Indicators 
  •  Increased Sounder outputs – 1A/24Vdc in main panel and 1A/24Vdc in the supplementary
  •  Increased Sounder outputs – 1A/24Vdc in main panel and 1A/24Vdc in the supplementary
  •  Redundant processor back up to the main one
  •  Inputs for fire extinguishing panel signals
  • Detection and exact location of dual address devices
  • Detection and exact location of a short circuit in the loop
  • Loop break notification
  • ModBUS TCP/IP protocol
  • Changeable company logo file on the main screen
  • Connectivity panel – Cloud server – mobile application for remote access for control, maintenance and programming

 

Attachment

iRIS8 B - Datasheet

Download

Brochure

Download

Related products

Compare

SensoIRIS S130 IS

alarms, Addressables, TELETEK
Operating Voltage Range 16 – 32VDC (Nom. 27VDC)
Consumption in quiescent state, no communication < 190μA@27VDC
Consumption in quiescent state, with communication < 310μA@27VDC
Consumption in alarm state, with communication 6.5mA
Output in alarm state at terminal RI (terminals 4/ 1) 7.5 mA (max)/ 7.5V
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP30
Weight (including base) ~125g
Dimensions (including base) 103x42mm
Add to wishlist
Quick view
Compare

SensoIRIS MIO22

Addressables, Modules
Operating Voltage Range 16 – 32VDC
Consumption, stand-by mode 235μA@27VDC
Outputs, electrical characteristics (max.) DC 30V/1A; AC 125V/0.5A
Consumption, 1 LED on 3.5 mA
Consumption, 2 LEDs on 7 mA
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP21C
Weight ~230g
Dimensions 142x80x45 mm
Add to wishlist
Quick view
Compare

SIMPO TTE Loop

alarms, Addressables, TELETEK, Modules
Maximum Current Consumption 0.5A
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +65°C
Weight ~30g
Dimensions 75x80mm
Add to wishlist
Quick view
Compare

Optical – Smoke Fire Alarm Detector

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Application

The S30 is a high sensitive optical smoke detector. It is suitable for applications where early detection of smoke or fire is with great importance, for example office buildings, supermarkets, schools, etc.
Add to wishlist
Quick view
Compare

SensoIRIS T110

alarms, Addressables, TELETEK
Operating Voltage Range 15-32VDC (Nom. 27VDC)
Consumption in quiescent state, no communication < 130μA@27VDC
Consumption in quiescent state, with communication < 180μA@27VDC
Consumption in alarm state, with communication 6.5mA
Output in alarm state at terminal RI (terminals 4/ 1) 7.5 mA (max)/ 7.5V
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +65°C
Protection IP30
Weight (including base) ~110g
Dimensions (including base) 103x42mm
Add to wishlist
Quick view
Compare

Manual Call Point

alarms, Addressables, LIFECO, Fire Alarm & Low Current System
Operating voltage 9 ÷ 30 VDC Nominal operating voltage 24 VDC Current consumption in alarm state 23mA/15V; 38mA/24V; 48mA/30V Installation wires 0,4mm2 ÷ 2.0mm2 Operation temperature -10°C ÷ +60°C Relative humidity ≤93% @ +40°C Type of the frangible element A Material (plastic), Color ABS, red Degree of protection IP40 Dimensions (incl. base) 90x57x90mm
Add to wishlist
Quick view
Compare

Repeater

alarms, Addressables, TELETEK, Control panel
Power Supply:
– from the panel AUX/GND
– external (24 ±4)VDC
Maximum power consumption 0.11A
Communication RS 485
Twisted pair cable UTP CAT 5:
– maximum length between repeater and panel max. 1000m.
– cross Section 0.5-2.5mm²
Protection class IP40
Color, Material White, ABS
Dimensions of panel 200x330x48mm
Maximum number of supported panels in network 64
Network type Ring topology
Memory LOG 10 000 events
Multi language support YES
Operating temperature -5°C to +50°C
Relative humidity resistance. 95%
Weight ~ 770g
Add to wishlist
Quick view
Hot
Compare

Robin Addressable Fire Alarm Control Panel

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Features

  • Available in 1, 2 & 4 Intelligent detection circuits
  • 5” LCD Display – 320x240dpi resolution
  • Up to 127 devices per loop.
  • Logic controlled output functions
  • 15 LED status indicators
  • 21 key user-friendly control switches
  • Laptop programming
  • Fully field programmable
Add to wishlist
Quick view
  • Riyadh, Malaz, At the intersection of Salah al-Din and Al - Sahrawi St. ​
  • Phone: (+966) 580709087
  • Phone: (+966) 593847589
  • Admin@fireendtrading.com
  • USEFUL Pages
    • About Us
    • Products
    • Our Projects
    • Certificates
    • Contact Us
  • Categories
    • Alarms
    • Boxes
    • Extinguishers
    • PUMPS
    • Sprinkler
    • Fire Hydrants
    • Valves
    • Pressure Tanks
  • Robin Addressable Fire Alarm Control Panel
  • 1 zone fire alarm control panel
  • Battery operated heat detector
  • SensoIRIS MIO04
  • SFFECO-227 system
Based on Fire End Trading theme 2023 GK.
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
Start typing to see products you are looking for.
Wishlist
Compare
Shop