Pressure Reducing Valve

  • Available sizes: 1 ½ and 2 ½ inch.
  • Adjustable fog, straight stream and shut off
  • Finish: Brass and Chrome
  • Thread: NST
  • NST to BS336 male adaptor available if required.
  • Nozzle pressure: 100 psi
  • Discharge GPM as in UL listing

Pressure Restricting Angle Hose Valve

LIFECO Pressure Restricting Angle Hose Valve is used with a fire hose reel or rack assemblies or as a fire department outlet connection. Water pressure is controlled up to 175psi by adjustable flow restriction. Locking pin mechanism restricts unnecessary frill opening of valve. Pin may be removed by trained personnel as needed.

Remote Paging Unit

Emergency Voice/Alarm Communications System Features & Benefits:
  • Smaller footprint than the ECS-RCU
  • Supervised Microphone
  • Connects to control panel via 4-wire SBUS and 2-wire VBUS
  • Eight emergency communication message buttons
  • 16 mappable audio switches
Certifications:
  • NFPA 70, & NFPA 72: Central Station- Remote Signalling- Local Protective Signalling Systems- Auxiliary Protected Premises Unit- & Water Deluge Releasing Service
  • P/N 351185 Rev C

Repeater

Power Supply:
– from the panel AUX/GND
– external (24 ±4)VDC
Maximum power consumption 0.11A
Communication RS 485
Twisted pair cable UTP CAT 5:
– maximum length between repeater and panel max. 1000m.
– cross Section 0.5-2.5mm²
Protection class IP40
Color, Material White, ABS
Dimensions of panel 200x330x48mm
Maximum number of supported panels in network 64
Network type Ring topology
Memory LOG 10 000 events
Multi language support YES
Operating temperature -5°C to +50°C
Relative humidity resistance. 95%
Weight ~ 770g

RPS-1000 Distributed Power Module

Features & Benefits:
  • 6.0 amps output power
  • Ground loop isolation and transient protection
  • Provides SBUS optical isolation and re-conditions the RS- 485 signal
  • Room to mount two 6815 or 5815XL SLC expander modules
  • Six onboard Flexput circuits programmable for:
  • Up to 6,000 foot wiring distance from the RPS-1000
  • Battery charging capacity is 35AH
Certifications:
  • UL Listed
  • CSFM
  • NFPA 13, NFPA 70, NFPA 72, UL 2572, UL 1711 & UL 864: Local Protective Signalling Systems;
  • City of New York: 429-92-E Vol IX

SensoIRIS CSOU

Operating Voltage Range 16 – 32VDC
Maximal consumption at communication 470 μА @ 27VDC
Maximal consumption (main tone type 27:
   – low volume level 3 mА @ 27VDC
   – high volume level 10 mА @ 27VDC
Power volume:
   – low volume (up to 100 pcs     sounders* to the loop). ~ 81dB (A) ± 3dB @ 1m
   – high volume (up to 30 pcs sounders* to the loop)  ~ 88dB (A) ± 3dB @ 1m
Wire Gauge for terminals 0.4 – 2.0mm2
Material and color ABS / White
Dimensions 105 х 22 mm
a

SensoIRIS CSST IS

Operating Voltage Range 16 – 32VDC
Maximal consumption at communication 470 μА @ 27VDC
Maximal consumption (main tone type 27:
   – low volume level 3 mА @ 27VDC
   – high volume level 10 mА @ 27VDC
Power volume:
   – low volume (up to 100 pcs     sounders* to the loop). ~ 81dB (A) ± 3dB @ 1m
   – high volume (up to 30 pcs sounders* to the loop)  ~ 88dB (A) ± 3dB @ 1m
Wire Gauge for terminals 0.4 – 2.0mm2
Material and color SAN, transparent / White
Dimensions 105 х 22 mm
 

SensoIRIS GAS

Power supply 24VDC
Power consumption <3W
Protection against electric shock: Class III
Power connection hard wired
Alarm threshold 10%LEL
Alarms sound level ≥ 85dB
Sensor type catalytic
Sensor lifetime 5 years
Detected gases LPG/CH4 (Methane)
Enclosure color White
Heating-up time 30 sec
Size 130х96х38mm
Weight 0,200kg
             

SensoIRIS M140

Operating Voltage Range 15 – 32VDC (Nom. 27VDC)
Consumption in quiescent state < 160μA@27VDC
Consumption in alarm state, with communication 6.5mA
Output in alarm state at terminal RI (terminals 4/ 1) 7.5 mA (max)/ 7.5V
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP30
Weight (including base) ~125g
Dimensions (including base) 103x42mm

SensoIRIS M140 IS

Operating Voltage Range 16-32VDC (Nom. 27VDC)
Consumption in quiescent state, no communication < 190μA@27VDC
Consumption in quiescent state, with communication < 310μA@27VDC
Consumption in alarm state, with communication 6.5mA
Output in alarm state at terminal RI (terminals 4/ 1) 7.5 mA (max)/ 7.5V
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP30
Weight (including base) ~125g
Dimensions (including base) 103x49mm
           

SensoIRIS MIMIC

Operating voltage 16 ÷ 32VDC
Max. current consumption <2mА @27VDC
Current consumption with PCB Status LED ON* 5.4mA
Outputs Characteristics:
Operating Voltage 12÷24VDC
Voltage for LEDs 12VDC
Max current consumption 390mA@ 24VDC/ 790mA@ 12VDC
Automatic current limitation of the outputs:  With Ri=0k With Ri=1k   15mA 10mA
Max. length of connection cable for LEDs 3m
Material/color (enclosure box)  ABS, Grey

SensoIRIS MiniOut

Relay switching power 60W, 62.5VA
Relative humidity resistance (93±3)%@+40°C
Operating voltage 15 ÷ 32V DC
Max. current consumption 0.1mA
Relay ratings 0.25A/24V AC; 2A/30V DC
Relay rated current 2A
Relay max. switching current 5A
Protection (with enclosure box) IP30
Relative humidity resistance (93±3)%@+40°C
Max. cross section of the cables 2.5mm2
Dimensions (PCB) 43x25mm
Mounting Indoor use