iRIS4
| Main Power Supply | 230VAC +10%/-15%,50÷60 Hz |
| Back-up Power Supply- lead batteries |
12V/18Ah |
| Nominally internal battery resistance |
<0,3Ohm |
| Storage Temperature | -10˚C to +60˚C |
| Operating temperature | -5°C to +40°C |
| Dust and moisture protection | IP 30 |
| Relative Humidity | up to 95%(without condense) |
| Dimensions | 430/330/120mm |
| Weight | 6kg(without battery) |
Categories: TELETEK, إنذار معنون, صفارات الإنذار, لوحة التحكم
Description
قابلة للتوسيع من 1 إلى 4 وحدات تحكم حلقة .
Attachment
Datasheet
DownloadRelated products
SensoIRIS MOUT-240
| Operating Voltage Range | 15 – 32VDC |
| Nominal consumption during communication | 220μA |
| Relay Parameters | 4A/ 250VAC; 3A/ 30VDC |
| Max. current consumption in STAND-BY mode | 175μA@27VDC |
| Wire Gauge for terminals | 0.4mm² – 2.0mm² |
| Operating temperature | -10°C to +60°C |
| Protection | IP40 |
| Weight | ~230g |
| Dimensions | 142x80x45 mm |
SensoIRIS MCP150
SensoIRIS S130
| Operating Voltage Range | 15 – 32VDC (Nom. 27VDC) |
| Consumption in quiescent state | < 160μA@27VDC |
| Consumption in alarm state, with communication | 6.5mA |
| Output in alarm state at terminal RI (terminals 4/ 1) | 7.5 mA (max)/ 7.5V |
| Wire Gauge for terminals | 0.4mm² – 2.0mm² |
| Operating temperature | -10°C to +60°C |
| Protection | IP30 |
| Weight (including base) | ~125g |
| Dimensions (including base) | 103x42mm |
SensoIRIS S130 IS
| Operating Voltage Range | 16 – 32VDC (Nom. 27VDC) |
| Consumption in quiescent state, no communication | < 190μA@27VDC |
| Consumption in quiescent state, with communication | < 310μA@27VDC |
| Consumption in alarm state, with communication | 6.5mA |
| Output in alarm state at terminal RI (terminals 4/ 1) | 7.5 mA (max)/ 7.5V |
| Wire Gauge for terminals | 0.4mm² – 2.0mm² |
| Operating temperature | -10°C to +60°C |
| Protection | IP30 |
| Weight (including base) | ~125g |
| Dimensions (including base) | 103x42mm |
Repeater
| Power Supply: | |
| – from the panel | AUX/GND |
| – external | (24 ±4)VDC |
| Maximum power consumption | 0.11A |
| Communication | RS 485 |
| Twisted pair cable UTP CAT 5: | |
| – maximum length between repeater and panel | max. 1000m. |
| – cross Section | 0.5-2.5mm² |
| Protection class | IP40 |
| Color, Material | White, ABS |
| Dimensions of panel | 200x330x48mm |
| Maximum number of supported panels in network | 64 |
| Network type | Ring topology |
| Memory LOG | 10 000 events |
| Multi language support | YES |
| Operating temperature | -5°C to +50°C |
| Relative humidity resistance. | 95% |
| Weight | ~ 770g |
SensoIRIS GAS
| Power supply | 24VDC |
| Power consumption | <3W |
| Protection against electric shock: | Class III |
| Power connection | hard wired |
| Alarm threshold | 10%LEL |
| Alarms sound level | ≥ 85dB |
| Sensor type | catalytic |
| Sensor lifetime | 5 years |
| Detected gases | LPG/CH4 (Methane) |
| Enclosure color | White |
| Heating-up time | 30 sec |
| Size | 130х96х38mm |
| Weight | 0,200kg |