Centrifugal Vertical Turbine Fire Pumps
- All Pumps are Hydrostatically Tested to minimum of 150% of its Maximum Working Pressure and can withstand Double the Max.Working Pressure.
- All Pumps have Clock-Wise Rotation when viewed from the Driver Side.
- All Pumps are Multistage with 2 stages as minimum requirement.
- “The rated speed marked on the pump can vary within +/-4% of the listed/ approved rated speed example: 3000 RPM pump can be driven with 2900 RPM Drivers.”
| Model No. | Capacity (GPM) | UL,SETSCO & CE Listed Net Pressure (PSI) | Number of Stages | FM Approved Rated Net Pressure (PSI) | Number of Stages | Approx Speed (RPM) |
|---|---|---|---|---|---|---|
| SFP-200-70VT | 200 | 40 – 248 | 2 – 12 | 40 – 289 | 2 – 12 | 1480 |
| SFP-200-70VT | 200 | 48 – 348 | 2 – 10 | 64 – 348 | 2 – 10 | 1480 |
| SFP-200-30VT | 200 | 60 – 305 | 2 – 6 | 2900 | ||
| SFP-200-30VT | 200 | 63 – 323 | 2 – 6 | 2980 | ||
| SFP-200-30VT | 200 | 64 – 327 | 2 – 6 | 3000 |
Categories: Centrifugal Pumps, PUMPS, SFFECO, Standard Fire Pumps Systems
Related products
Photoelectric smoke detector
Model No.: LE-SOC-24V
Features
Computer Designed Non-directional Smoke Chamber
360° View of Detector Case
Low Profile, 1.8" Height (with Base)
2 or 4 Wire Base Compatibility, Relay Bases Available
Very Stable Operation, RF/
Standby Current Transient Protection Low, 59μA at 24VDC
Two Built-in Power/Sensitivity Lights for Supervision/Alarm
The automatic sensitivity window check function meets the requirements specified in NFPA 72, Chapters 2 and 7, Inspection, Testing, and Maintenance.
Jockey pumps
Gmax Custom Fire Pumps
Diesel Tanks
Thermo-Act Fire Extinguishing System
Thermo-Act fire suppression system
SFFECO Thermo-Act Systems is the advanced technology for automatic fire suppression systems. The systems offer a self-activating suppression system that puts out fires in seconds. It is simple to design and install with low maintenance, cost effective and reliable. Neither electrical nor pneumatic sources should be required for our thermal effect systems. The systems can be used in the presence of an increased risk of fire. SFFECO Thermo-Act systems use fire retardant flexible tube to detect fires. Thus, the fire detection and extinguishing system is not required for detection and discharge. SFFECO Thermo-Act systems can be designed with available commercial agents including clean agents, wet chemicals, foam, and dry powder. The system can be arranged as a direct system or an indirect system.Fire pump controllers
Centrifugal End Suction Fire Pumps
| Model No. | Rated Capacity (GPM) | Size(SucXDis) (inches) | UL Listed Rated Net Pressure Range (PSI) | FM Approved Rated Net Pressure Range (PSI) | SETSCO & CE Pressure(PSI) | Approx Speed (RPM) | Max Working Pressure (PSI) |
|---|---|---|---|---|---|---|---|
| SFP-50-20 EM-2G | 50 | 2 ½ X 2 | 74 - 93 | 74 - 93 | 74 - 93 | 2900 | 180 |
| SFP-50-20 EM-2G | 50 | 2 ½ X 2 | 79 - 99 | 79 - 99 | 79 - 99 | 3000 | 180 |
| SFP 50-20 EM | 50 | 2 x 1 ¼ | 68 - 87 | 68 - 88 | 68 - 87 | 2900 | 230 |
| SFP 50-20 EH | 50 | 2 x 1 ¼ | 101 -129 | 102 - 129 | 101 -129 | 3500 | 230 |
| SFP 50-26 EM | 50 | 2 x 1 ¼ | 115 -140 | 115 - 133 | 115 -140 |