WE SAFE YOUR LIFE

  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
فاير اند | Fire end فاير اند | Fire end
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
Search
Menu
Home TELETEK Modules SensoIRIS MIO04
SensoIRIS MIMIC
Back to products
Angle Hose Valve

SensoIRIS MIO04

Operating Voltage Range 15 – 32VDC
Consumption, stand-by mode 175μA@27VDC
Nom. current consumption 200µA@27VDC
Outputs, electrical characteristics (max.) DC 30V/1A; AC 125V/0,5A
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP40
Weight ~230g
Dimensions 142x80x45 mm
Add to wishlist
Categories: Addressables, Modules
Share:
  • Description
  • Attachment
Description

Description

SensoIRIS MIO04 is an addressable module with 4 relay outputs. The module is designed for application in addressable fire alarm systems, supporting TTE communication protocol.

The module controls 4 relay outputs.

SensoIRIS MIO04 is powered on from the fire panel and can be controlled via the communication protocol.

The module is mounted in a separate small plastic box suitable for wall mounting, with transparent cover for visual inspection.

BOSEC certified.

  • 4 Relay outputs
  • Loop powered
  • Built in isolator
  • Placed in plastic box with transparent cover for easy inspection
  • EN54-18 and EN54-17:2005 certified
Attachment

Datasheet

Download

BOSEC certificate

Download

Related products

Hot
Compare

Robin Addressable Fire Alarm Control Panel

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Features

  • Available in 1, 2 & 4 Intelligent detection circuits
  • 5” LCD Display – 320x240dpi resolution
  • Up to 127 devices per loop.
  • Logic controlled output functions
  • 15 LED status indicators
  • 21 key user-friendly control switches
  • Laptop programming
  • Fully field programmable
Add to wishlist
Quick view
Compare

iRIS8 B

Addressables, Control panel
Main Power Supply  110÷230VAC,50÷60 Hz, 2x200W
 Back-up Power Supply- lead batteries one in the main block + one in the Block expander 12V/ 18Ah
Nominally internal battery resistance  <0,3Ohm
Storage Temperature -10˚C to +60˚C
Operating temperature -5°C to +40°C
Dust and moisture protection IP30
Relative Humidity (without condense) up to 95%
Dimensions 660/430/120mm
 Weight 15kg (without battery)
Add to wishlist
Quick view
Compare

Temperature Fire Alarm Detector

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Application

The F10 is suitable for environments, where sudden large temperature changes are considered as normal, rooms with high concentration of vaporous, exhaust gases, dust, etc. For example: kitchens, garages, boiler rooms or other places where it is not convenient to install fire alarm optical smoke detectors.
Add to wishlist
Quick view
Compare

SensoIRIS S130

alarms, Addressables, TELETEK
Operating Voltage Range 15 – 32VDC (Nom. 27VDC)
Consumption in quiescent state < 160μA@27VDC
Consumption in alarm state, with communication 6.5mA
Output in alarm state at terminal RI (terminals 4/ 1) 7.5 mA (max)/ 7.5V
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP30
Weight (including base) ~125g
Dimensions (including base) 103x42mm
Add to wishlist
Quick view
Compare

SensoIRIS MOUT-240

alarms, Addressables, TELETEK, Modules
Operating Voltage Range 15 – 32VDC
Nominal consumption during communication 220μA
Relay Parameters 4A/ 250VAC; 3A/ 30VDC
Max. current consumption in STAND-BY mode 175μA@27VDC
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP40
Weight ~230g
Dimensions 142x80x45 mm
Add to wishlist
Quick view
Compare

SensoIRIS MCP150

alarms, Addressables, TELETEK, Sirens
Operating Voltage Range 15 – 32VDC
Consumption without communication (max) 125μA@27VDC
Consumption in Fire mode 3mA
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP40
Weight ~175g
Dimensions 90x90x57mm
Add to wishlist
Quick view
Hot
Compare

MCP Cover Set

alarms, Addressables, Conventional, TELETEK
Compatible with SensoMAG MCP50 and SensoIRIS MCP150
Add to wishlist
Quick view
Compare

Robin fire alarm addressable control panel

alarms, Addressables, LIFECO, Fire Alarm & Low Current System
Model Number: LF-6100A/1, LF-6100A/2 & LF-6100A/4 Attributes Available in 1, 2 and 4 Smart Detection Circuits 5" LCD Display - 320 x 240 dpi Resolution Up to 127 devices each episode. Logic-controlled output functions 15 LED status indicators 21 user-friendly control keys Laptop programming Full field programming
Add to wishlist
Quick view
  • Riyadh, Malaz, At the intersection of Salah al-Din and Al - Sahrawi St. ​
  • Phone: (+966) 580709087
  • Phone: (+966) 593847589
  • Admin@fireendtrading.com
  • USEFUL Pages
    • About Us
    • Products
    • Our Projects
    • Certificates
    • Contact Us
  • Categories
    • Alarms
    • Boxes
    • Extinguishers
    • PUMPS
    • Sprinkler
    • Fire Hydrants
    • Valves
    • Pressure Tanks
  • Sounder
  • Twin-heads Emergency Light
  • EJ Type - Standard Pumps
  • Wet Base
  • SensoIRIS MIMIC
Based on Fire End Trading theme 2023 GK.
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
Start typing to see products you are looking for.
Wishlist
Compare
Shop