Mechanical Joint – 300PSI
- Complies with AWWA C515 Standard
- NPT plug on body
- 300PSI Working pressure
- Ductile Iron Body
- Sizes: 3”, 4”, 6”, 8”, 10” & 12” – UL Listed
- Sizes: 2.5”, 3”, 4”, 5”, 6”, 8”, 10” & 12” – FM Approved
Categories: LIFECO, NRS Type Gate Valves, Valves
Attachment
Related products
1 zone fire alarm control panel
Food Processor Model Number: Eagle 1
Features
1 Fixed Zones
Supports up to 32 Detectors
Unlimited Contact Points
1 “Fire” and 1 “Fault” relay outputs 1 Monitored safer
outputs Active EOL allowing continuous monitoring of inputs Walk test LED indicator Access levels Protected by a security key, a plastic box, Abdulaziz Street Company, only for 599
Emergency Light/Exit Light
LIFECO, Emergency and Exit Lights, Fire Alarm & Low Current System, alarms, Doors , Frames and Exit signs
End suction fire pump
LIFECO pumps undergo the required inspection, tests and production control during the assembly process and records are kept for the same, before they are delivered to our customers. Each pump is produced, and subjected to performance tests as follows:
a) Test run
performance curves plotted showing efficiency, brake force (kW), and total head developed at shutdown, at rated capacity, at 150 percent of rated capacity, And at selected intermediate capacities between closing and maximum capacities exceeding 150% of the rated capacity.
b) Hydrostatic Test
Each pump shall be hydrostatically tested for a minimum of 5 minutes. The test pressure shall be up to two times
the maximum working pressure of the pump, but in no case less than 250 psi (1724 kPa) to ensure that there is no
rupture or leakage through the castings at the test pressure.
c) Motor Balance
The impellers of each pump are dynamically balanced with a balance quality grade of G6.3 accordingly
with the requirements for the pumps impellers in the Mechanical Vibration Standard – Balance Quality
2 zone fire alarm control panel
Robin Addressable Fire Alarm Control Panel
Grooved Ends – Gear Operated
Addressable analog control panel
2 to 8 episodes or 2 to 16 episodes
127 addressable points per SLC loop
Single or dual slot (includes area LED module and printer)
Modular and expandable electronics
4 programmable NACs; Class B or 2 Class A
7 inch color resistive touch screen with easy to use user interface
Power supply options (5.25A or 10.25A)
Programmable (3) inputs and (5) relay outputs
Networkable with programmable functions
Coincidences are OR and AND in cause and effect
Programming via USB or PC