Diesel Tanks
All LIFECO Steel Above ground Tanks for flammable and combustible Liquid are assembled and tested to all requirements as follows * ANSI/UL-142 – Compliant. * Installation standard compliance to NFPA 30, NFPA 30A and NFPA 31 * Primary and Secondary containment
Categories: Diesel Tanks, Fire Pump, LIFECO, PUMPS
Attachment
Related products
Standard Fire Pumps Systems
Range
- Speed: 2900 – 3500 RPM
- Frequency 50 / 60 Hz
- Capacity 50 GPM – 1500 GPM
- Pressure Range 100 PSI – 261 PSI
Types
- Available as Self Standing Wall Mounted Base Mounted
- Configurations Available EDJ Type EJ Type DJ Type
- Pressure Tanks are available as optional
- SFFECO Control Panels are included in the package
Centrifugal Horizontal Split Case Fire Pumps
- All Pumps are Hydrostatically Tested to minimum of 150% of its Maximum Working Pressure and can withstand Double the Max.Working Pressure.
- All Pumps have Clock-Wise Rotation when viewed from the Driver Side.
- All Pumps are horizontal single stage Pumps.
- “The rated speed marked on the pump can vary within +/-4% of the listed/ approved rated speed example: 3000 RPM pump can be driven with 2900 RPM Drivers.”
Model No. | Rated Capacity (GPM) | Size (SucXDis) | UL Listed Rated Net Pressure Range (PSI) | FM Approved Rated Net Pressure Range (PSI) | SETSCO & CE Rated Net Pressure Range (PSI) | Approx Speed (RPM) | Max Working Pressure (PSI) |
---|---|---|---|---|---|---|---|
SFP150-25SH | 150 | 6 x 4 | 114-208 | 114-208 | 114-208 | 3500 | 300 |
SFP150-25SH | 150 | 6 x 4 | 121-220 | 121-220 | 121-220 | 3600 | 300 |
SFP150-40SM | 150 | 6 x 4 | 206-289 | 206-289 | 206-289 | 2900 | 385 |
SFP150-40SM | 150 | 6 x 4 | 221-310 | 221-310 | 221-310 | 3000 | 385 |
SFP150-SN31SH | 150 | 6 x 4 | 226-316 | 226-316 | 226-316 |
2 zone fire alarm control panel
4 zone fire alarm control panel
Fire Pump Controllers
Caprari P6 – P18 Series
Centrifugal Vertical Turbine Fire Pumps
- All Pumps are Hydrostatically Tested to minimum of 150% of its Maximum Working Pressure and can withstand Double the Max.Working Pressure.
- All Pumps have Clock-Wise Rotation when viewed from the Driver Side.
- All Pumps are Multistage with 2 stages as minimum requirement.
- “The rated speed marked on the pump can vary within +/-4% of the listed/ approved rated speed example: 3000 RPM pump can be driven with 2900 RPM Drivers.”
Model No. | Capacity (GPM) | UL,SETSCO & CE Listed Net Pressure (PSI) | Number of Stages | FM Approved Rated Net Pressure (PSI) | Number of Stages | Approx Speed (RPM) |
---|---|---|---|---|---|---|
SFP-200-70VT | 200 | 40 - 248 | 2 - 12 | 40 - 289 | 2 - 12 | 1480 |
SFP-200-70VT | 200 | 48 - 348 | 2 - 10 | 64 - 348 | 2 - 10 | 1480 |
SFP-200-30VT | 200 | 60 - 305 | 2 - 6 | 2900 | ||
SFP-200-30VT | 200 | 63 - 323 | 2 - 6 | 2980 | ||
SFP-200-30VT | 200 | 64 - 327 | 2 - 6 | 3000 |
EJ Type – Standard Pumps
EDJ Type Models
Flow (GPM) | Skid Width (mm) | Skid Height (mm) | Skid Length (mm) | Motor (HP) | Jockey (HP/GPM) | Header Pipe |
---|---|---|---|---|---|---|
50 | 700 | 1230 | 830 | 5.5 | 3 / 10 | 1.5" |
120 / 150 | 800 | 1250 | 1220 | 15 | 3 / 10 | 2" |
250 / 300 | 800 | 1420 | 1220 | 30 | 3 / 15 | 4" |
500 | 900 | 1660 | 1350 | 5.5 | 5.5 / 25 |