WE SAFE YOUR LIFE

  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
Search
Menu
New
Home LIFECO Alarm Check Valves Wet Alarm Check valve
Alarm Check Valves
Back to products
DELUGE VALVES

Wet Alarm Check valve

  • Anti-corrosive Trim
  • Cast iron body for extra hydrostatic strength
  • Quick removal and easy service for rubber-faced clapper
  • Maximum working pressure : 175psi for 4” & 6”, 250psi for 8”
Add to wishlist
Categories: Alarm Check Valves, LIFECO
Share:
  • Description
  • Attachment
Description

Description

As an essential part of a wet sprinkler system, LIFECO UL Listed Wet Alarm Valve is used as a device that detects water flow in the fire equipment installed in residential area, manufacturing area, and so on. The valve is designed to initiate an alarm during a sustained flow of water (such as the flow required by an open sprinkler) by operating an optional water motor alarm and/or a pressure switch.
Attachment

Datasheet

Download

Related products

Hot
Compare

Wet barrel fire hydrant

Fire Hydrants, LIFECO
DESCRIPTION MATERIALS SPECIFICATIONS Model LF-WBHX-115 / LF-WBHX-100 Faucet, Wet Barrel Type, 6" Diameter Made of Ductile Iron, with Single 4.5" Pump Connection (4" Pump Connection Optional ). 2.5" Thread Hose Outlet Connections and Connectors , AWWA C503, Flangeless 4" Display, UL\FM Approved, LIFECO Model LF-WBHM-115 / LF-WBHM-100 Faucet, Wet Barrel Type, 6" Diameter Made of Ductile Iron, With Single Pump Connection 4.5” (4″ Pump Connection Optional) Thread and Hose Outlet Connections 2.5” Thread, AWWA C503, With Only 4” Flange Display, UL\FM Approved, LIFECO Features Strong Ductile Iron Material for Long Service Life Pressure Rating Higher at 250psi and 2 times the 500psi test pressure • Choice of multiple hose nozzles • Internal and external fusion bonded epoxy coating • FM approved and UL Listed for use in fire protection application • Observation flange available for additional hardware Technical Specifications • Design Standard: FM1511 / UL246 / AWWA C503 • Nozzle Thread Standard: NFPA1963 • Pressure Working: 250 psi • Inlet Flange Connection in ANSI Class 125/150 6" BS EN 1092-2PN110 / 16 6” • Observation Flange Connection in ANSI Class125/150 4” • Hose Nozzle: 2.5″ * 2 • Nozzle Pump: 4.5” * 1 (4” pump connection optional) • Monitor Flange Connection 2H1PM: ANSI Class125 / 1504 “ BS EN 1092-2 PN10 / 16 4” • Inlet Flange Connection: ANSI CIass125 / 150 6” BS EN1092-2 PN10/16 6” Component Material No. 1 Hydrant Body 65-45-12 2 Steel Wire Rope 3 0 EPDM Ring 4 Fire Engine Nozzle Cap 65-45-12 SS304 Plastic Coated 5 Fire Engine Nozzle C84400 6 Fire Engine Nozzle EPDM Gasket 7 4.5” Gland C F8 8 Inner Flat Angle Set Six Corners Spoiled A 2 9 4.5” EPDM Sealing Ring Disc 10 Disc 4.5” CF8 11 55304/55420 12 Fixed Nut CF8 13 Inner Six Cylinder Angles Head Cover A2.70 14 C84400 15 C & 8 16 Hex Nuts 4.5” Shaft Nut A2.70 17 Hose Nozzle Cap Run Nut
Add to wishlist
Quick view
Compare

Diesel Driven Skids

LIFECO, Fire Pump, PUMPS
LIFECO Diesel Driven Centrifugal Fire Pump Skids are available in combinations of both Listed and Approved Centrifugal End Suction Pumps and Centrifugal Horizontal Split Case Pumps coupled with Listed Diesel Engine Drivers
Add to wishlist
Quick view
Compare

Temperature Fire Alarm Detector

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Application

The F10 is suitable for environments, where sudden large temperature changes are considered as normal, rooms with high concentration of vaporous, exhaust gases, dust, etc. For example: kitchens, garages, boiler rooms or other places where it is not convenient to install fire alarm optical smoke detectors.
Add to wishlist
Quick view
Compare

Audible and visual alarm indicator

LIFECO, Fire Alarm & Low Current System, alarms

Features

  • Built-in CPU
  • Addressable Output Device
  • With a Gradual function, sudden shock can be avoided
  • Piezoelectric Horn
  • Automatic or Manual Activation
  • Data Transfer Speed and Reliability
  • High Performance at Low Cost
  • Wall Mount Type
  • Four Wire Operation
  • Use LF-DP-6190 for device addressing
Add to wishlist
Quick view
Compare

Relay Output Module

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Features

  • Low Profile Design
  • Built-in CPU
  • Fast and Accurate response time
  • Feedback Monitoring
  • Data Transfer Speed and Reliability
  • Polarized Wiring
  • LED Status Indicators
  • High Performance at Low Cost
  • Two Wire System
  • Use LF-DP-6190 for device addressing
Add to wishlist
Quick view
Hot
Compare

Robin Addressable Fire Alarm Control Panel

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Features

  • Available in 1, 2 & 4 Intelligent detection circuits
  • 5” LCD Display – 320x240dpi resolution
  • Up to 127 devices per loop.
  • Logic controlled output functions
  • 15 LED status indicators
  • 21 key user-friendly control switches
  • Laptop programming
  • Fully field programmable
Add to wishlist
Quick view
Compare

End suction fire pump

LIFECO, Fire Pump, PUMPS
LIFECO pumps undergo the required inspection, tests and production control during the assembly process and records are kept for the same, before they are delivered to our customers. Each pump is produced, and subjected to performance tests as follows: a) Test run performance curves plotted showing efficiency, brake force (kW), and total head developed at shutdown, at rated capacity, at 150 percent of rated capacity, And at selected intermediate capacities between closing and maximum capacities exceeding 150% of the rated capacity. b) Hydrostatic Test Each pump shall be hydrostatically tested for a minimum of 5 minutes. The test pressure shall be up to two times the maximum working pressure of the pump, but in no case less than 250 psi (1724 kPa) to ensure that there is no rupture or leakage through the castings at the test pressure. c) Motor Balance The impellers of each pump are dynamically balanced with a balance quality grade of G6.3 accordingly with the requirements for the pumps impellers in the Mechanical Vibration Standard – Balance Quality
Add to wishlist
Quick view
Compare

Sounder with Beacon

alarms, Conventional, LIFECO, Fire Alarm & Low Current System, Sounders
Model No.:  LF-1010RFX , LF-1010RSX , LF-1010WFX  & LF-1010WSX A product designed for conventional fire alarm systems, it is an
Add to wishlist
Quick view
  • Riyadh, Malaz, At the intersection of Salah al-Din and Fatima al-Zahra ​
  • Phone: (+966) 580709087
  • Phone: (+966) 593847589
  • Purchase@fireend.net
  • USEFUL Pages
    • About Us
    • Products
    • Our Projects
    • Certificates
    • Contact Us
  • Categories
    • Alarms
    • Boxes
    • Extinguishers
    • PUMPS
    • Sprinkler
    • Fire Hydrants
  • Gmax Custom Fire Pumps
  • SF100 WSST
  • EJ Type - Standard Pumps
Based on Fire End Trading theme 2023 GK.
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
Start typing to see products you are looking for.
Wishlist
Compare
Shop