DELUGE VALVES
- Available nominal size: 200, 150, 100, 80 & 50NB
- 12 Bar (175 PSI) Pressure
- 90° pattern inlet to outlet vertical mounting
- Specialized Smoke Chamber Design
- Galvanized Steel with Brass Valves Trim
- 25 bar (350psi) Hydrostatic test pressure.
Categories: DELUGE VALVES, LIFECO, Valves, Valves
Attachment
Related products
Horizontal Sidewall Sprinkler
Conventional Fire Alarm Bell
Addressable analog control panel
2 to 8 episodes or 2 to 16 episodes
127 addressable points per SLC loop
Single or dual slot (includes area LED module and printer)
Modular and expandable electronics
4 programmable NACs; Class B or 2 Class A
7 inch color resistive touch screen with easy to use user interface
Power supply options (5.25A or 10.25A)
Programmable (3) inputs and (5) relay outputs
Networkable with programmable functions
Coincidences are OR and AND in cause and effect
Programming via USB or PC
Manual Call Point
Operating voltage 9 ÷ 30 VDC
Nominal operating
voltage 24 VDC
Current consumption in
alarm state
23mA/15V; 38mA/24V;
48mA/30V
Installation wires 0,4mm2 ÷ 2.0mm2
Operation temperature -10°C ÷ +60°C
Relative humidity ≤93% @ +40°C
Type of the frangible
element A
Material (plastic), Color ABS, red
Degree of protection IP40
Dimensions (incl. base) 90x57x90mm
Gas extinguishing panel
Model Number: LF/EX
Attributes
Solid steel powder-coated cabinet
Built-in battery and internal charger
System status indicator
Charge & error indicators. Battery failure
Alarm circuits monitored for both open and short circuit
Manual trigger switch on front
2 monitored detection zones
Gas release
knockout monitored on top and bottom sides for easy installation
Communication relay
Control switch Release
timer
Optical – Smoke Fire Alarm Detector
End suction fire pump
LIFECO pumps undergo the required inspection, tests and production control during the assembly process and records are kept for the same, before they are delivered to our customers. Each pump is produced, and subjected to performance tests as follows:
a) Test run
performance curves plotted showing efficiency, brake force (kW), and total head developed at shutdown, at rated capacity, at 150 percent of rated capacity, And at selected intermediate capacities between closing and maximum capacities exceeding 150% of the rated capacity.
b) Hydrostatic Test
Each pump shall be hydrostatically tested for a minimum of 5 minutes. The test pressure shall be up to two times
the maximum working pressure of the pump, but in no case less than 250 psi (1724 kPa) to ensure that there is no
rupture or leakage through the castings at the test pressure.
c) Motor Balance
The impellers of each pump are dynamically balanced with a balance quality grade of G6.3 accordingly
with the requirements for the pumps impellers in the Mechanical Vibration Standard – Balance Quality