Diesel Tanks
All LIFECO Steel Above ground Tanks for flammable and combustible Liquid are assembled and tested to all requirements as follows * ANSI/UL-142 – Compliant. * Installation standard compliance to NFPA 30, NFPA 30A and NFPA 31 * Primary and Secondary containment
Categories: Diesel Tanks, Fire Pump, LIFECO, PUMPS
Attachment
Related products
DJ Type – Standard Pumps
| Flow (GPM) | Skid Width (mm) | Skid Height (mm) | Skid Length (mm) | Diesel Engine (HP) | Jockey (HP/GPM) | Header Pipe |
|---|---|---|---|---|---|---|
| 50 | 700 | 1230 | 830 | 10 | 3 / 10 | 1.5" |
| 120 / 150 | 800 | 1280 | 1220 | 25 | 3 / 10 | 2" |
| 250 / 300 | 800 | 1420 | 1220 | 25 | 3 / 15 | 4" |
| 500 | 1000 | 1670 | 1600 | 60 | 5.5 / 25 | 6" |
| 750 | 1100 | 1760 | 1700 | 85 | 5.5 / 35 |
Battery operated smoke detector
Model Number: LF-SD41
Attributes
Photoelectric technology is more sensitive in detecting large particle fires
Perfect mounting system allows for easy installation and positioning
Dust cover included to keep the alarm clean during construction
9V backup battery included
One button test/silence
Smart technology designed to help reduce Unwanted nuisance alarms
Easy installation/maintenance
EDJ Type – Standard Pumps
| Flow (GPM) | Skid Width (mm) | Skid Height (mm) | Skid Length (mm) | Diesel Engine (HP) | Motor (HP) | Jockey (HP/GPM) | Header Pipe |
|---|---|---|---|---|---|---|---|
| 50 | 650 | 1250 | 1230 | 8 | 5.5 | 3 / 10 | 2" |
| 120 / 150 | 1220 | 1300 | 1220 | 15 | 15 | 3 / 10 | 2.5" |
| 250 / 300 | 1220 | 1420 | 1220 | 25 | 30 | 3 / 15 | 4" |
| 350 | 1550 | 1630 | 1600 | 40 | 40 | 3 / 20 | 4" |
| 500 | 1600 | 1420 | 1800 | 60 | 50 | 5.5 / 25 | 6" |
| 750 | 1700 | 1300 | 1800 | 85 | 75 | 5.5 / 35 | 6" |
| 1000 | 1700 | 1250 | 2000 | 100 | 100 |
4 zone fire alarm control panel
Centrifugal Vertical Turbine Fire Pumps
- All Pumps are Hydrostatically Tested to minimum of 150% of its Maximum Working Pressure and can withstand Double the Max.Working Pressure.
- All Pumps have Clock-Wise Rotation when viewed from the Driver Side.
- All Pumps are Multistage with 2 stages as minimum requirement.
- “The rated speed marked on the pump can vary within +/-4% of the listed/ approved rated speed example: 3000 RPM pump can be driven with 2900 RPM Drivers.”
| Model No. | Capacity (GPM) | UL,SETSCO & CE Listed Net Pressure (PSI) | Number of Stages | FM Approved Rated Net Pressure (PSI) | Number of Stages | Approx Speed (RPM) |
|---|---|---|---|---|---|---|
| SFP-200-70VT | 200 | 40 - 248 | 2 - 12 | 40 - 289 | 2 - 12 | 1480 |
| SFP-200-70VT | 200 | 48 - 348 | 2 - 10 | 64 - 348 | 2 - 10 | 1480 |
| SFP-200-30VT | 200 | 60 - 305 | 2 - 6 | 2900 | ||
| SFP-200-30VT | 200 | 63 - 323 | 2 - 6 | 2980 | ||
| SFP-200-30VT | 200 | 64 - 327 | 2 - 6 | 3000 |
2 zone fire alarm control panel
Standard Fire Pumps Systems
Range
- Speed: 2900 – 3500 RPM
- Frequency 50 / 60 Hz
- Capacity 50 GPM – 1500 GPM
- Pressure Range 100 PSI – 261 PSI
Types
- Available as Self Standing Wall Mounted Base Mounted
- Configurations Available EDJ Type EJ Type DJ Type
- Pressure Tanks are available as optional
- SFFECO Control Panels are included in the package