Repeater TFT IRIS/SIMPO
| Power Supply: From the panel External power supply unit | AUX/GND (24±4)VDC |
| Maximum power consumption | 0.11A |
| Communication | RS 485 |
| Twisted pair cable UTP CAT 5: Maximum length between repeater and panel Cross Section | max. 1000m 0.5-2.5mm2 |
| Degree of protection | IP40 |
| Color, Material | Grey, ABS |
| Operation temperature | -5ºС up to +40ºC |
| Relative humidity | up to 95% (without condense) |
| Storage temperature | -10ºС up to |
Robin fire alarm addressable control panel
Model Number: LF-6100A/1, LF-6100A/2 & LF-6100A/4
Attributes
Available in 1, 2 and 4 Smart Detection Circuits
5" LCD Display - 320 x 240 dpi Resolution
Up to 127 devices each episode.
Logic-controlled output functions
15 LED status indicators
21 user-friendly control keys
Laptop programming
Full field programming
SensoIRIS MIO22
| Operating Voltage Range | 16 – 32VDC |
| Consumption, stand-by mode | 235μA@27VDC |
| Outputs, electrical characteristics (max.) | DC 30V/1A; AC 125V/0.5A |
| Consumption, 1 LED on | 3.5 mA |
| Consumption, 2 LEDs on | 7 mA |
| Wire Gauge for terminals | 0.4mm² – 2.0mm² |
| Operating temperature | -10°C to +60°C |
| Protection | IP21C |
| Weight | ~230g |
| Dimensions | 142x80x45 mm |
SensoIRIS MOUT-240
| Operating Voltage Range | 15 – 32VDC |
| Nominal consumption during communication | 220μA |
| Relay Parameters | 4A/ 250VAC; 3A/ 30VDC |
| Max. current consumption in STAND-BY mode | 175μA@27VDC |
| Wire Gauge for terminals | 0.4mm² – 2.0mm² |
| Operating temperature | -10°C to +60°C |
| Protection | IP40 |
| Weight | ~230g |
| Dimensions | 142x80x45 mm |
SensoIRIS S130
| Operating Voltage Range | 15 – 32VDC (Nom. 27VDC) |
| Consumption in quiescent state | < 160μA@27VDC |
| Consumption in alarm state, with communication | 6.5mA |
| Output in alarm state at terminal RI (terminals 4/ 1) | 7.5 mA (max)/ 7.5V |
| Wire Gauge for terminals | 0.4mm² – 2.0mm² |
| Operating temperature | -10°C to +60°C |
| Protection | IP30 |
| Weight (including base) | ~125g |
| Dimensions (including base) | 103x42mm |
SensoIRIS T110
| Operating Voltage Range | 15-32VDC (Nom. 27VDC) |
| Consumption in quiescent state, no communication | < 130μA@27VDC |
| Consumption in quiescent state, with communication | < 180μA@27VDC |
| Consumption in alarm state, with communication | 6.5mA |
| Output in alarm state at terminal RI (terminals 4/ 1) | 7.5 mA (max)/ 7.5V |
| Wire Gauge for terminals | 0.4mm² – 2.0mm² |
| Operating temperature | -10°C to +65°C |
| Protection | IP30 |
| Weight (including base) | ~110g |