WE SAFE YOUR LIFE

  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
فاير اند | Fire end فاير اند | Fire end
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
  • EnglishEnglish
    • العربيةالعربية
    • EnglishEnglish
Search
Menu
Home TELETEK Control panel SIMPO
IRIS8 Loop Extension
Back to products
Repeater

SIMPO

Main Power Supply 90 ÷ 264 VAC
Frequency 47 ÷ 440 Hz
Back-up Power Supply 1 battery, 12V/ 18Ah
Electrical output 4.2A
Operating temperature -5°C to +40°C
Weight (without battery) 4.2kg
Dimensions 306x412x81.2mm
Add to wishlist
Categories: Addressables, alarms, Control panel, Sirens, TELETEK
Share:
  • Description
  • Attachment
Description

Description

  • Loops: Up to 2 (TTE protocol)
  • Devices per loop: 250
  • Zones: 48
  • Inputs: 3
  • Outputs (monitored, relay type): 5
  • Outputs (non monitored, programmable, relay type): 4, 15A@24VDC
  • Memory LOG: 10 240 events
  • Panels in RS485 redundant network (optional module): Up to 64
  • Thermal printer: Optional
  • Display: 4*40 symbols LCD
  • Multi language support: Yes
  • Programming:  ProsTE software
  • Standard: EN54 – 2/4
  • Transmitting events to monitoring software Observer via LAN channel (ModBUS protocol)
Attachment

Datasheet

Download

EN 54 Certificate EVPU

Download

EN 54-13 Certificate KIWA

Download

Related products

Compare

Temperature Fire Alarm Detector

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Application

The F10 is suitable for environments, where sudden large temperature changes are considered as normal, rooms with high concentration of vaporous, exhaust gases, dust, etc. For example: kitchens, garages, boiler rooms or other places where it is not convenient to install fire alarm optical smoke detectors.
Add to wishlist
Quick view
Compare

Gas extinguishing panel

LIFECO, Fire Alarm & Low Current System, alarms
Model Number: LF/EX Attributes Solid steel powder-coated cabinet Built-in battery and internal charger System status indicator Charge & error indicators. Battery failure Alarm circuits monitored for both open and short circuit Manual trigger switch on front 2 monitored detection zones Gas release knockout monitored on top and bottom sides for easy installation Communication relay Control switch Release timer
Add to wishlist
Quick view
Compare

Battery operated smoke detector

LIFECO, Fire Alarm & Low Current System, alarms
Model Number: LF-SD41 Attributes Photoelectric technology is more sensitive in detecting large particle fires Perfect mounting system allows for easy installation and positioning Dust cover included to keep the alarm clean during construction 9V backup battery included One button test/silence Smart technology designed to help reduce Unwanted nuisance alarms Easy installation/maintenance
Add to wishlist
Quick view
Compare

Sounder with Beacon

alarms, Conventional, LIFECO, Fire Alarm & Low Current System, Sounders
Model No.:  LF-1010RFX , LF-1010RSX , LF-1010WFX  & LF-1010WSX A product designed for conventional fire alarm systems, it is an
Add to wishlist
Quick view
Compare

SensoIRIS MOUT-240

alarms, Addressables, TELETEK, Modules
Operating Voltage Range 15 – 32VDC
Nominal consumption during communication 220μA
Relay Parameters 4A/ 250VAC; 3A/ 30VDC
Max. current consumption in STAND-BY mode 175μA@27VDC
Wire Gauge for terminals 0.4mm² – 2.0mm²
Operating temperature -10°C to +60°C
Protection IP40
Weight ~230g
Dimensions 142x80x45 mm
Add to wishlist
Quick view
Compare

Manual Call Point

alarms, Addressables, LIFECO, Fire Alarm & Low Current System
Operating voltage 9 ÷ 30 VDC Nominal operating voltage 24 VDC Current consumption in alarm state 23mA/15V; 38mA/24V; 48mA/30V Installation wires 0,4mm2 ÷ 2.0mm2 Operation temperature -10°C ÷ +60°C Relative humidity ≤93% @ +40°C Type of the frangible element A Material (plastic), Color ABS, red Degree of protection IP40 Dimensions (incl. base) 90x57x90mm
Add to wishlist
Quick view
Compare

Signal Input Module

alarms, Addressables, LIFECO, Fire Alarm & Low Current System

Features

  • Low Profile Design
  • Built-in CPU
  • Interfaces Normally Open Dry Contacts
  • ALARM FIRST! – Less than 1 second
  • Data Transfer Speed and Reliability
  • Polarized Wiring
  • LED Status Indicators
  • High Performance at Low Cost
  • Two Wire System
  • Use LF-DP-6190 for device addressing
Add to wishlist
Quick view
Compare

Robin fire alarm addressable control panel

alarms, Addressables, LIFECO, Fire Alarm & Low Current System
Model Number: LF-6100A/1, LF-6100A/2 & LF-6100A/4 Attributes Available in 1, 2 and 4 Smart Detection Circuits 5" LCD Display - 320 x 240 dpi Resolution Up to 127 devices each episode. Logic-controlled output functions 15 LED status indicators 21 user-friendly control keys Laptop programming Full field programming
Add to wishlist
Quick view
  • Riyadh, Malaz, At the intersection of Salah al-Din and Al - Sahrawi St. ​
  • Phone: (+966) 580709087
  • Phone: (+966) 593847589
  • Admin@fireendtrading.com
  • USEFUL Pages
    • About Us
    • Products
    • Our Projects
    • Certificates
    • Contact Us
  • Categories
    • Alarms
    • Boxes
    • Extinguishers
    • PUMPS
    • Sprinkler
    • Fire Hydrants
    • Valves
    • Pressure Tanks
  • SensoIRIS S130 IS
  • SensoIRIS CSST IS
  • 4 zone fire alarm control panel
  • Addressable analog control panel
  • Robin fire alarm addressable control panel
Based on Fire End Trading theme 2023 GK.
  • Home
  • About Us
  • Our Projects
  • Products
    • alarms
      • Addressables
      • Conventional
    • Cabinets
    • Caprari
      • BOOSTER SETS
      • Borehole pumps
      • centrifugal pumps
      • Control and protection devices
      • Dry installed sewage electric pumps
      • ELECTRIC PANELS
      • Frequency converter
      • Horizontal Pumps
      • Sewage Pumps
      • Submersible Motors
      • Vertical lineshaft pumps
      • Vertical pumps
    • Extinguishers
    • LIFECO
      • Fire Alarm & Low Current System
      • OS&Y Gate Valves
      • NRS Type Gate Valves
      • DELUGE VALVES
      • Diesel Tanks
      • Alarm Check Valves
      • sprinkler
      • Valves
      • Emergency and Exit Lights
      • Switches
    • SFFECO
      • Fire Pump
      • Cabinets
      • Self-extinguishing systems
      • Standard Fire Pumps Systems
      • Doors and Exits Signs
    • TELETEK
    • VTI
    • PUMPS
    • Pressure Tanks
    • sprinkler
  • Certificates
  • Catalogue
  • Contact us
Start typing to see products you are looking for.
Wishlist
Compare
Shop