Pressure Reducing Valve
- Pressure Reducing Valve: Reducing a higher upstream pressure into a lower, constant downstream pressure
- Operates over a wide flow range
- Set Pressure is adjustable with single screw
- Can be maintained without removal from the pipe line.
- Flanged to EN1092-2 PN10/PN16, ANSI B16.1 Class 150 FF (Other available on request)
- Grooved Ends to AWWA C606 Standard
- Adjustment Range of Outlet Pressure: 65 to 165 psi
- Rated Working Pressure: 300 psi
- Fusion Bonded Epoxy Coated Interior and Exterior to AWWA C550 Standard.
Related products
Horizontal Sidewall Sprinkler
Wet barrel fire hydrant
DESCRIPTION MATERIALS SPECIFICATIONS Model
LF-WBHX-115 / LF-WBHX-100
Faucet, Wet Barrel Type, 6" Diameter Made of Ductile Iron, with
Single 4.5" Pump Connection (4" Pump Connection Optional
). 2.5" Thread Hose Outlet Connections and Connectors
, AWWA C503, Flangeless 4" Display, UL\FM
Approved, LIFECO
Model LF-WBHM-115 / LF-WBHM-100
Faucet, Wet Barrel Type, 6" Diameter Made of Ductile Iron, With
Single Pump Connection 4.5” (4″ Pump Connection
Optional) Thread and Hose Outlet Connections 2.5”
Thread, AWWA C503, With Only 4” Flange Display, UL\FM
Approved, LIFECO
Features
Strong Ductile Iron Material for Long Service Life
Pressure Rating Higher at 250psi and 2 times
the 500psi test pressure
• Choice of multiple hose nozzles
• Internal and external fusion bonded epoxy coating
• FM approved and UL Listed for use in
fire protection application
• Observation flange available for additional hardware
Technical Specifications
• Design Standard: FM1511 / UL246 / AWWA C503
• Nozzle Thread Standard: NFPA1963
• Pressure Working: 250 psi
• Inlet Flange Connection in ANSI Class 125/150 6"
BS EN 1092-2PN110 / 16 6”
• Observation Flange Connection in ANSI Class125/150 4”
• Hose Nozzle: 2.5″ * 2
• Nozzle Pump: 4.5” * 1 (4” pump connection optional)
• Monitor Flange Connection 2H1PM: ANSI Class125 / 1504 “
BS EN 1092-2 PN10 / 16 4”
• Inlet Flange Connection: ANSI CIass125 / 150 6”
BS EN1092-2 PN10/16 6”
Component Material No.
1 Hydrant Body 65-45-12
2 Steel Wire Rope
3 0 EPDM Ring
4 Fire Engine Nozzle Cap 65-45-12
SS304 Plastic Coated
5 Fire Engine Nozzle C84400
6 Fire Engine Nozzle EPDM Gasket
7 4.5” Gland C F8
8 Inner Flat Angle Set Six Corners Spoiled A 2 9 4.5” EPDM Sealing Ring Disc
10 Disc 4.5” CF8 11 55304/55420 12 Fixed Nut CF8 13 Inner Six Cylinder Angles Head Cover A2.70 14 C84400 15 C & 8 16 Hex Nuts 4.5” Shaft Nut A2.70 17 Hose Nozzle Cap Run Nut
Addressable analog control panel
2 to 8 episodes or 2 to 16 episodes
127 addressable points per SLC loop
Single or dual slot (includes area LED module and printer)
Modular and expandable electronics
4 programmable NACs; Class B or 2 Class A
7 inch color resistive touch screen with easy to use user interface
Power supply options (5.25A or 10.25A)
Programmable (3) inputs and (5) relay outputs
Networkable with programmable functions
Coincidences are OR and AND in cause and effect
Programming via USB or PC
Battery operated heat detector
Gas extinguishing panel
Model Number: LF/EX
Attributes
Solid steel powder-coated cabinet
Built-in battery and internal charger
System status indicator
Charge & error indicators. Battery failure
Alarm circuits monitored for both open and short circuit
Manual trigger switch on front
2 monitored detection zones
Gas release
knockout monitored on top and bottom sides for easy installation
Communication relay
Control switch Release
timer
Photoelectric smoke detector
Model No.: LE-SOC-24V
Features
Computer Designed Non-directional Smoke Chamber
360° View of Detector Case
Low Profile, 1.8" Height (with Base)
2 or 4 Wire Base Compatibility, Relay Bases Available
Very Stable Operation, RF/
Standby Current Transient Protection Low, 59μA at 24VDC
Two Built-in Power/Sensitivity Lights for Supervision/Alarm
The automatic sensitivity window check function meets the requirements specified in NFPA 72, Chapters 2 and 7, Inspection, Testing, and Maintenance.
Robin Addressable Fire Alarm Control Panel
Manual Call Point
Operating voltage 9 ÷ 30 VDC
Nominal operating
voltage 24 VDC
Current consumption in
alarm state
23mA/15V; 38mA/24V;
48mA/30V
Installation wires 0,4mm2 ÷ 2.0mm2
Operation temperature -10°C ÷ +60°C
Relative humidity ≤93% @ +40°C
Type of the frangible
element A
Material (plastic), Color ABS, red
Degree of protection IP40
Dimensions (incl. base) 90x57x90mm