Thermo-Act Fire Extinguishing System
Thermo-Act fire suppression system
SFFECO Thermo-Act Systems is the advanced technology for automatic fire suppression systems. The systems offer a self-activating suppression system that puts out fires in seconds. It is simple to design and install with low maintenance, cost effective and reliable. Neither electrical nor pneumatic sources should be required for our thermal effect systems. The systems can be used in the presence of an increased risk of fire.
SFFECO Thermo-Act systems use fire retardant flexible tube to detect fires. Thus, the fire detection and extinguishing system is not required for detection and discharge.
SFFECO Thermo-Act systems can be designed with available commercial agents including clean agents, wet chemicals, foam, and dry powder. The system can be arranged as a direct system or an indirect system.
Related products
Fire Rated Cabinets
FK-5-1-12 Extinguishing System
Standard Fire Pumps Systems
Range
- Speed: 2900 – 3500 RPM
- Frequency 50 / 60 Hz
- Capacity 50 GPM – 1500 GPM
- Pressure Range 100 PSI – 261 PSI
Types
- Available as Self Standing Wall Mounted Base Mounted
- Configurations Available EDJ Type EJ Type DJ Type
- Pressure Tanks are available as optional
- SFFECO Control Panels are included in the package
Fire doors and frames
Fire doors and frames
As part of our continuous pursuit of innovation, SFFECO has launched its world-class fire rated doors and frames. The fire doors and frames are manufactured in a fully automated factory using CNC machines thus ensuring uniform quality and a great finish. SFFECO fire doors are manufactured to comply with various architectural requirements. These doors are designed for areas where strength, stability and durability are priorities. Typical applications include industrial building entrances, shop service doors, basement floors, stairwells, and elevator shafts. It is also widely used as partition or exterior doors in electrical and petrochemical plants. The door or frame can be made of cold rolled steel, galvanized steel or stainless steel. Doors can be used in drywall and masonry construction.Mobile Foam Fire Extinguishers
| Model | TF25 | TF10G | TF50 | TF100 | TF35G | TFC50 | TFC100 | TFC35G |
|---|---|---|---|---|---|---|---|---|
| Capacity (L) | 25 | 37.8 | 50 | 100 | 132 | 50 | 100 | 132 |
| Effective Range | 8 m | 8 m | 8 m | 8 m | 8 m | 8 m | 8 m | 8 m |
| Discharge Duration | 19-23 Sec | 29-33 Sec | 38-42 Sec | 77-82 Sec | 100-105 Sec | 42-45 Sec | 82-85 Sec | 110-120 Sec |
| Working Pressure | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar | 12-15 bar |
EJ Type – Standard Pumps
EDJ Type Models
| Flow (GPM) | Skid Width (mm) | Skid Height (mm) | Skid Length (mm) | Motor (HP) | Jockey (HP/GPM) | Header Pipe |
|---|---|---|---|---|---|---|
| 50 | 700 | 1230 | 830 | 5.5 | 3 / 10 | 1.5" |
| 120 / 150 | 800 | 1250 | 1220 | 15 | 3 / 10 | 2" |
| 250 / 300 | 800 | 1420 | 1220 | 30 | 3 / 15 | 4" |
| 500 | 900 | 1660 | 1350 | 5.5 | 5.5 / 25 |
Fire pump controllers
Fire Hose Reels & Accessories
| model | measuring | classification |
|---|---|---|
| SH19R | 19 mm | Type A, Class 2 |
| SH25R | 25 mm | Type A, Class 2 |
| model | manual | automatic |
|---|---|---|
| static type | SF 30 F-19 SF 30 F-25 | sf 30 AF-19 sf 30 AF-25 |
| Swing tube type | SF 30 SP-19 SF 30 SP-25 | SF 30 A-SP-19 SF 30 A-SP-25 |
| swing arm type | SF 30 SA-19 SF 30 SA-25 | SF 30 A-SA-19 SF 30 A-SA-25 |